đźšš Free Worldwide Shipping on All Orders!Shop Now
HomeStore

Lancer 115V 3/4 HP 8-Valve CED-MED 800 Dispenser - 385-25208XS-111X20

Product image 1

Lancer 115V 3/4 HP 8-Valve CED-MED 800 Dispenser - 385-25208XS-111X20

Lancer 115V 3/4 HP 8-Valve CED-MED 800 Dispenser - 385-25208XS-111X20

The Lancer 115V 3/4 HP 8 Valve CED-MED 800 Dispenser is a premium high-volume beverage station. It utilizes a massive 3/4 HP refrigeration deck to build a thermal ice-bank battery, ensuring that all 8 circuits remain at 40F or below even during extreme serving surges in cafeterias or high-traffic restaurants.

What it Solves: Corrects 'warm soda' in locations without a remote chiller. This unit provides a self-contained high-capacity cooling solution that ensures crisp carbonation and brand-standard flavor profiles regardless of customer demand.

Symptoms of Failure: Warm serving temperatures during peak surges, refrigeration deck failing to build an ice bank, or the internal agitator motor failing to move the water bath.

Technician’s Note: Maintain a minimum of 4 inches of clearance on all sides for airflow. Restricted ventilation is the primary cause of compressor overheating. Periodically check the water bath level to ensure probe continuity.
Technical Specifications:
  • Voltage: 115V / 60Hz
  • Compressor: 3/4 HP High-Load
  • Valve Count: 8 LEV Precision Valves
  • Cooling: Internal Ice Bank (CED)
$1,796.91

Original: $5,134.04

-65%
Lancer 115V 3/4 HP 8-Valve CED-MED 800 Dispenser - 385-25208XS-111X20—

$5,134.04

$1,796.91

Product Information

Shipping & Returns

Description

The Lancer 115V 3/4 HP 8 Valve CED-MED 800 Dispenser is a premium high-volume beverage station. It utilizes a massive 3/4 HP refrigeration deck to build a thermal ice-bank battery, ensuring that all 8 circuits remain at 40F or below even during extreme serving surges in cafeterias or high-traffic restaurants.

What it Solves: Corrects 'warm soda' in locations without a remote chiller. This unit provides a self-contained high-capacity cooling solution that ensures crisp carbonation and brand-standard flavor profiles regardless of customer demand.

Symptoms of Failure: Warm serving temperatures during peak surges, refrigeration deck failing to build an ice bank, or the internal agitator motor failing to move the water bath.

Technician’s Note: Maintain a minimum of 4 inches of clearance on all sides for airflow. Restricted ventilation is the primary cause of compressor overheating. Periodically check the water bath level to ensure probe continuity.
Technical Specifications:
  • Voltage: 115V / 60Hz
  • Compressor: 3/4 HP High-Load
  • Valve Count: 8 LEV Precision Valves
  • Cooling: Internal Ice Bank (CED)