The Lancer 230V 3/4HP 3/4 HP Chiller 2500 3/4HP 230V/50 4 Circuits is a high-capacity refrigeration unit designed to maintain beverage product lines at serving temperatures in remote-run systems. Utilizing a 3/4 HP refrigeration deck, it builds a massive thermal ice bank to ensure consistent 40F drinks even during peak rush surges.

What it Solves: Provides a self-contained cooling solution that ensures beverages remain served at 40F or below. Perfect for satellite bars or auxiliary towers where the main carbonator is located in a distant back-room.

Symptoms of Failure: Beverages served warm at the tower, refrigeration deck failing to build an ice bank, or findings of 'ice-bridging' in the water bath which blocks the agitator motor.

Technician’s Note: Maintain at least 4 inches of clearance on all sides for optimal airflow. Restricted ventilation is the primary cause of compressor overheating. Check the water bath level monthly to ensure probe conductivity.
Technical Specifications:
  • Voltage: 230V
  • Compressor: 3/4 HP
  • Circuit Count: 4 Circuits
  • Cooling Type: Remote Ice Bank Chiller
$4,542.91
Lancer 230V 3/4 HP Chiller 2500, 4 Circuits - 85-2654A—
$4,542.91

Product Information

Shipping & Returns

Description

The Lancer 230V 3/4HP 3/4 HP Chiller 2500 3/4HP 230V/50 4 Circuits is a high-capacity refrigeration unit designed to maintain beverage product lines at serving temperatures in remote-run systems. Utilizing a 3/4 HP refrigeration deck, it builds a massive thermal ice bank to ensure consistent 40F drinks even during peak rush surges.

What it Solves: Provides a self-contained cooling solution that ensures beverages remain served at 40F or below. Perfect for satellite bars or auxiliary towers where the main carbonator is located in a distant back-room.

Symptoms of Failure: Beverages served warm at the tower, refrigeration deck failing to build an ice bank, or findings of 'ice-bridging' in the water bath which blocks the agitator motor.

Technician’s Note: Maintain at least 4 inches of clearance on all sides for optimal airflow. Restricted ventilation is the primary cause of compressor overheating. Check the water bath level monthly to ensure probe conductivity.
Technical Specifications:
  • Voltage: 230V
  • Compressor: 3/4 HP
  • Circuit Count: 4 Circuits
  • Cooling Type: Remote Ice Bank Chiller