🚚 Free Worldwide Shipping on All Orders!Shop Now
HomeStore

Lancer Condenser Turbo FIN 500 - 23-0955-SP

Product image 1

Lancer Condenser Turbo FIN 500 - 23-0955-SP

Lancer Condenser Turbo FIN 500 - 23-0955-SP

The Lancer Condenser Turbo FIN 500 is the primary heat-rejection component for the refrigeration deck. Featuring a high-surface-area 'Turbo FIN' design, it is engineered to rapidly dissipate heat from the compressed refrigerant, allowing the system to maintain a consistent ice bank in the water bath even during peak summer ambient temperatures.

Problem Solved: Restores essential thermal management and prevents compressor burnout. Replaces pitted or clogged condensers that cause high head pressures, leading to inefficient cooling and warm beverage Serving temperatures.

Symptoms of Failure: Compressor running 24/7 without building an ice bank, the unit frame feeling excessively hot to the touch, or finding the refrigeration deck frequenting thermal overload trips.

Technician’s Note: Clean the fins monthly with a soft brush or compressed air. Dust and grease buildup on the condenser is the #1 cause of premature compressor failure in commercial dispensers. Ensure the fan motor is moving at full RPM when the compressor is engaged.
Technical Specifications:
  • Manufacturer: Lancer
  • Application: Condenser Heat Exchange
  • Technology: Turbo FIN High-Efficiency
  • Compatibility: Lancer 500 Series Refrigeration Decks
$68.35
Lancer Condenser Turbo FIN 500 - 23-0955-SP—
$68.35

Product Information

Shipping & Returns

Description

The Lancer Condenser Turbo FIN 500 is the primary heat-rejection component for the refrigeration deck. Featuring a high-surface-area 'Turbo FIN' design, it is engineered to rapidly dissipate heat from the compressed refrigerant, allowing the system to maintain a consistent ice bank in the water bath even during peak summer ambient temperatures.

Problem Solved: Restores essential thermal management and prevents compressor burnout. Replaces pitted or clogged condensers that cause high head pressures, leading to inefficient cooling and warm beverage Serving temperatures.

Symptoms of Failure: Compressor running 24/7 without building an ice bank, the unit frame feeling excessively hot to the touch, or finding the refrigeration deck frequenting thermal overload trips.

Technician’s Note: Clean the fins monthly with a soft brush or compressed air. Dust and grease buildup on the condenser is the #1 cause of premature compressor failure in commercial dispensers. Ensure the fan motor is moving at full RPM when the compressor is engaged.
Technical Specifications:
  • Manufacturer: Lancer
  • Application: Condenser Heat Exchange
  • Technology: Turbo FIN High-Efficiency
  • Compatibility: Lancer 500 Series Refrigeration Decks