🚚 Free Worldwide Shipping on All Orders!Shop Now
HomeStore

Lancer Redundant Electronic Ice Bank Control Probe - 52-2088/01-SP

Product image 1

Lancer Redundant Electronic Ice Bank Control Probe - 52-2088/01-SP

Lancer Redundant Electronic Ice Bank Control Probe - 52-2088/01-SP

The Lancer Probe Assembly Redundant Electronic Ice Bank Control is a specialized safety and management sensor responsible for monitoring the thickness of the ice bank in the water bath. The redundant design ensures that if one circuit fails, the backup circuit prevents the compressor from freezing the entire tank solid.

Problem Solved: Restores accurate system feedback to the control board, preventing refrigeration freeze-ups or overflow conditions. Corrects logic errors where the compressor fails to cycle off.

Symptoms of Failure: Compressor running 24/7, ice bank overgrowth that blocks the agitator, or the unit failing to build any ice bank despite having power (due to false 'full' signal).

Technician’s Note: Clean probe tips with a non-metallic abrasive pad. Mineral deposits act as an insulator, causing the board to misread water bath conductivity. Ensure the wire harness is secured away from the agitator propeller.Technical Specifications:
  • Manufacturer: Lancer
  • Application: Ice Bank Control (IBC) Management
  • Type: Redundant Dual-Circuit Probe
  • Compatibility: Standard Lancer Refrigeration Decks
$40.67
Lancer Redundant Electronic Ice Bank Control Probe - 52-2088/01-SP—
$40.67

Product Information

Shipping & Returns

Description

The Lancer Probe Assembly Redundant Electronic Ice Bank Control is a specialized safety and management sensor responsible for monitoring the thickness of the ice bank in the water bath. The redundant design ensures that if one circuit fails, the backup circuit prevents the compressor from freezing the entire tank solid.

Problem Solved: Restores accurate system feedback to the control board, preventing refrigeration freeze-ups or overflow conditions. Corrects logic errors where the compressor fails to cycle off.

Symptoms of Failure: Compressor running 24/7, ice bank overgrowth that blocks the agitator, or the unit failing to build any ice bank despite having power (due to false 'full' signal).

Technician’s Note: Clean probe tips with a non-metallic abrasive pad. Mineral deposits act as an insulator, causing the board to misread water bath conductivity. Ensure the wire harness is secured away from the agitator propeller.Technical Specifications:
  • Manufacturer: Lancer
  • Application: Ice Bank Control (IBC) Management
  • Type: Redundant Dual-Circuit Probe
  • Compatibility: Standard Lancer Refrigeration Decks