🚚 Free Worldwide Shipping on All Orders!Shop Now
HomeStore

Lancer Sleeve Probe for Delta III and CCD8000 - 05-0436

Product image 1

Lancer Sleeve Probe for Delta III and CCD8000 - 05-0436

Lancer Sleeve Probe for Delta III and CCD8000 - 05-0436

The Lancer Sleeve Probe for Delta III and CCD8000 is the specialized thermal sensing interface for the refrigeration water bath. It encapsulates the sensing wire to prevent direct moisture contact while ensuring rapid thermal transfer to the control board, allowing for precise management of the ice bank thickness.

Problem Solved: Restores accurate system feedback to the control board, preventing freeze-ups or cooling loss. Replaces cracked sleeves that allow water to bypass the sensor, leading to false resistance readings.

Symptoms of Failure: Compressor running 24/7, ice bank overgrowth that blocks the agitator propeller, or the unit failing to build any ice bank despite power.

Technician’s Note: Clean mineral scale from the sleeve exterior during every PM. Lime buildup acts as an insulator, slowing the thermal response of the probe and causing the ice bank to grow too thick (bridging).
Technical Specifications:
  • Manufacturer: Lancer
  • Application: Ice Bank Control (IBC) Logic
  • Compatibility: Delta III and CCD8000 Series
  • Type: High-Conductivity Thermal Sleeve
$1.43

Original: $4.08

-65%
Lancer Sleeve Probe for Delta III and CCD8000 - 05-0436—

$4.08

$1.43

Product Information

Shipping & Returns

Description

The Lancer Sleeve Probe for Delta III and CCD8000 is the specialized thermal sensing interface for the refrigeration water bath. It encapsulates the sensing wire to prevent direct moisture contact while ensuring rapid thermal transfer to the control board, allowing for precise management of the ice bank thickness.

Problem Solved: Restores accurate system feedback to the control board, preventing freeze-ups or cooling loss. Replaces cracked sleeves that allow water to bypass the sensor, leading to false resistance readings.

Symptoms of Failure: Compressor running 24/7, ice bank overgrowth that blocks the agitator propeller, or the unit failing to build any ice bank despite power.

Technician’s Note: Clean mineral scale from the sleeve exterior during every PM. Lime buildup acts as an insulator, slowing the thermal response of the probe and causing the ice bank to grow too thick (bridging).
Technical Specifications:
  • Manufacturer: Lancer
  • Application: Ice Bank Control (IBC) Logic
  • Compatibility: Delta III and CCD8000 Series
  • Type: High-Conductivity Thermal Sleeve